Aflatoxins B1 ELISA Test Kit for Feed

The Aflatoxin B1 ELISA Test Kit is a competitive ELISA for the qualitative or quantitative analysis of aflatoxin B1 in feed and feed material.
RM 200.00

Background:

Aflatoxins are toxic and carcinogenic. They are metabolites of the fungi Aspergillus flavus and Aspergillus parasiticus. There are four principle types of aflatoxin: B1, B2, G1 and G2, which are named for their respective innate fluorescent properties. Aflatoxin B1 is the most frequently encountered of the group and the most toxic one. Aflatoxins can be found mainly in cereals, nuts, cottonseed and human blood.

Aflatoxin B1 is a potent human carcinogen, and may contribute to human liver cancer.

Manufacturer Meizheng
Trademark ToxinFast®
Order No. HEM0496
Analyte Aflatoxins B1
Sample Type Feed and feed material
Methodology Indirect competitive enzyme-labeled immunoassay.
Packaging 96 Wells
Storage The kits should be stored at a dry place away from the sunlight and the storage temperature is 2-8˚C. DO NOT FREEZE!
Shelf life The validity for this kit is 12 months
Lead time Shipped within 5-12 working days.
Cross Reactivity AFB1……………………………………100%
AFB2……………………………………38%
AFG1……………………………………27%
AFG2……………………………………4%
AFM1………………..…………………20%
AFM2……………………………………<1%
Calculate Result Please use the professional analysis instruments of Elisa kit for calculation, which is more accurate and fast to get result for kinds of samples
Limit of detection 1.5µg/kg
Limit of quantitation 1.5µg/kg
Percent Recovery, % 100±20%
Precision (CV %): Intra-lab assay: CV%≤10%

Provided Materials and Reagent:

Component QTY
Antigen coated plate 12×8 wells each
5 vials of Standard 1mL each
AFB1 Enzyme Conjugate 12mL
AFB1 Antibody Solution 12mL
Substrate 10mL*2
Concentrated Wash buffer (10×) 40mL
Package Insert 1
Plate Cover Sheet 2
Testing Report 1

Note: The concentrations of the standards are 0µg/kg, 1.5µg/kg, 5µg/kg, 15µg/kg and 50µg/kg respectively (the real concentration of the standards is 1/25 of the set concentrations).

Materials Required But Not Provided

  1. Devices:

---- Microwell plate Reader (450nm/630nm)

---- Oscillator/ Vortex

---- Thermostat incubator

---- Centrifuge (or quantitative filter)

---- Balance (sensibility: 0.01g)

---- Pipette: 50mL

---- Triangular flask (with stopper): 100mL

---- Centrifuge tube: 7mL

---- Micropipet: Single channel pipet (10µL-100µL, 100µL-1000µL)  Multi-channel pipet (30µL-300µL)

  1. Reagent:

---- Methanol (AR)

---- Deionized water

---- Concentrated sulfuric acid (18 mol/L)

Note: The pictures shown are sample product pictures.

For the actual product, please check Provided Materials and Reagent or consult the sales manager.